July 26, 2010
Novell Data Synchronizer and the GroupWise Connector provide the foundation for synchronizing data between GroupWise and Salesforce.com, SharePoint, and SugarCRM.
NOTE:This configuration does not include synchronization with mobile devices.
System requirements are listed in the Novell Data Synchronizer Installation Guide.
Make sure that the Linux server where you plan to install Data Synchronizer and the GroupWise Connector meets the system requirements.
If a Web server is currently running on the Synchronizer server, stop it, and preferably disable it.
Download the Novell Data Synchronizer ISO file to a convenient temporary directory:
novell-data-synchronizer-x86_64.iso
On your Linux desktop, click root password.
> , then enter theUnder
, click , then click .Install Data Synchronizer as an add-on product.
Complete installation instructions are available in the Novell Data Synchronizer Installation Guide.
When you run the Data Synchronizer Installation program in YaST, you might see the following error:
The proposal contains an error that must be resolved before continuing
This error indicates that you clicked
without providing the configuration information for your Synchronizer system. Instead of clicking , click , then provide the configuration as prompted. After you provide the configuration information, click .In the Data Synchronizer Installation program on SLES 11 SP1, if you browse to and select the Data Synchronizer ISO file, you receive the following error:
ISO image file not responding
As a workaround, type the full path and filename for the ISO file instead of browsing to it.
If you already have Python packages installed on the server where you are installing Data Synchronizer, the Data Synchronizer Installation program needs to update the existing packages, rather than install new packages. This does not happen by default.
When you run the Installation program, you see a list of all the packages that need to be installed. Review this list for packages that need to be updated. Click any existing packages so that the Update icon is displayed, then continue with the Data Synchronizer installation.
Data Synchronizer must be installed on a server with a 64-bit/x86 processor. If you try to install it on a server with a 32-bit/x86 processor, the Data Synchronizer Installation program does not detect the problem. It tries to run, but it cannot run correctly.
If the behavior of the Data Synchronizer Installation program does not match the installation instructions provided in the Novell Data Synchronizer Installation Guide, make sure that you are installing Data Synchronizer on a server that meets the documented system requirements.
There are currently no plans to make Data Synchronizer available in a 32-bit version.
Use only alphanumeric characters in the Synchronizer database password. Do not include special characters. The Sync Engine does not start if the database password includes special characters.
Before you run the Data Synchronizer Installation program, you must create a GroupWise trusted application so that the GroupWise Connector can log into a GroupWise Post Office Agent (POA) in order to access GroupWise mailboxes without needing personal user passwords. When setting up the GroupWise Connector as a trusted application, you only need to fill in three fields in the Create Trusted Application dialog box in ConsoleOne: , , and . Do not fill in any other fields. If you fill in additional fields, the trusted application does not work correctly with the GroupWise Connector.
If you have been participating in the Data Synchronizer beta, you might need to delete the existing Synchronizer certificate on workstations where you access Synchronizer Web Admin. You need to delete the existing certificate if you receive the following error when you try to access Synchronizer Web Admin:
Secure Connection Failed
An error occurred during a connection to ip_address.
You have received an invalid certificate.
To delete the existing Synchronizer certificate in Firefox:
Click
.Click
.Click
.Select the certificate named DataSync Web Admin, then click Delete.
Click OK to close the various Firefox dialog boxes, then log in to Synchronizer Web Admin.
If the LDAP server is restarted while Synchronizer is running, Synchronizer loses its connection to the LDAP server. Occasionally, the connection to the LDAP server is lost for other reasons. To reestablish the connection, restart the Synchronizer services.
When the Sync Engine is stopped or restarted, it forces all connectors to stop as well. After the Sync Engine is restarted, restart the Connector Manager service. After the Connector Manager service is restarted, restart each connector in Synchronizer Web Admin or configure the connectors to start automatically.
When you use a group to add a large number of users to a connector (for example, 1000 users), all users might not be added to the connector during the same LDAP poll cycle. You can refresh the Add Users page or watch the log file for the connector to see when the process of adding users to the connector has been completed.
A similar problem can occur if you add multiple groups that collectively include a large number of users.
When you add or delete a large number of users or groups, the Manage Users page or the Manage Groups page might not display the presence or absence of the users or groups correctly. Refresh the page in your browser to display the users or groups correctly.
If a user’s LDAP username includes a space, the user cannot log in to the Data Synchronizer User Options page.
In order to delete users from a connector, the connector must be running. If the connector is not running, some user event data is not properly deleted.
When you stop a connector in Synchronizer Web Admin and then start it again immediately, the status might indefinitely remain as
. This can happen because the connector did not completely stop before you tried to restart it. The connector might have been completing a polling cycle before shutting down, even though Synchronizer Web Admin displayed the status as . When you try to start a connector that is still shutting down, it cannot start normally.To restart the connector when this situation has occurred:
Restart the Connector Manager on the command line:
rcdatasync-connectors restart
This should change the connector status in Synchronizer Web Admin from
to .Start the connector in Synchronizer Web Admin.
Start any other connectors that stopped as a result of restarting the Connector Manager.
Some connectors restart automatically when the Connector Manager restarts.
If this problem occurs repeatedly, wait a few seconds between the time when you stop the connector and when you start it again to allow the connector to shut down completely before restarting.
Synchronizer Web Admin allows you to manually create multiple instances of the same connector. This configuration is not currently supported.
If you have more users than a single connector can service, you can install one or more additional instances of Data Synchronizer until all users are being successfully serviced.
Refer to the Readme for each connector on the Novell Data Synchronizer Connectors Documentation Web site.
Novell Data Synchronizer documentation is available at the Novell Data Synchronizer Documentation Web site:
Novell Data Synchronizer Readme
Novell Data Synchronizer installation and administration guides
Novell Data Synchronizer connector documentation is available at the Novell Data Synchronizer Connector Documentation Web site
Connector Readmes
Connector Quick Starts
Connector installation and configuration guides
In addition to the Data Synchronizer product documentation, the following resources provide additional information about Data Synchronizer:
Novell, Inc. makes no representations or warranties with respect to the contents or use of this documentation, and specifically disclaims any express or implied warranties of merchantability or fitness for any particular purpose. Further, Novell, Inc. reserves the right to revise this publication and to make changes to its content, at any time, without obligation to notify any person or entity of such revisions or changes.
Further, Novell, Inc. makes no representations or warranties with respect to any software, and specifically disclaims any express or implied warranties of merchantability or fitness for any particular purpose. Further, Novell, Inc. reserves the right to make changes to any and all parts of Novell software, at any time, without any obligation to notify any person or entity of such changes.
Any products or technical information provided under this Agreement may be subject to U.S. export controls and the trade laws of other countries. You agree to comply with all export control regulations and to obtain any required licenses or classification to export, re-export, or import deliverables. You agree not to export or re-export to entities on the current U.S. export exclusion lists or to any embargoed or terrorist countries as specified in the U.S. export laws. You agree to not use deliverables for prohibited nuclear, missile, or chemical biological weaponry end uses. Please refer to the Novell International Trade Services Web page for more information on exporting Novell software. Novell assumes no responsibility for your failure to obtain any necessary export approvals.
Copyright © 2010 Novell, Inc. All rights reserved. No part of this publication may be reproduced, photocopied, stored on a retrieval system, or transmitted without the express written consent of the publisher.
For Novell trademarks, see the Novell Trademark and Service Mark list.
All third-party trademarks are the property of their respective owners.