A ZENworks 11 server is compatible with ZENworks Configuration Management 10.3.x managed devices. However, a newly installed ZENworks 11 server cannot provide component management functionality to ZENworks 10.3.x managed devices communicating with it unless these steps are taken.
Copy the following files from a ZENworks 10.3.x server or a system updated ZENworks 11 server in the zone and replace them at the respective location of the newly installed ZENworks 11 server.
On Linux:
/opt/novell/zenworks/install/downloads/novell-*.msi
/opt/novell/zenworks/install/downloads/novell-*.msi.superceded
On Windows:
%ZENWORKS_HOME%\install\downloads\novell-*.msi
%ZENWORKS_HOME%\install\downloads\novell-*.msi.superceded
Location where the files must be copied on the newly installed ZENworks 11 server:
On Linux:
/opt/novell/zenworks/install/downloads/
/opt/novell/zenworks/install/downloads/
On Windows:
%ZENWORKS_HOME%\install\downloads\
%ZENWORKS_HOME%\install\downloads\
NOTE:On Linux, ensure all the copied files have zenworks:zenworks ownership. To set the appropriate ownership for these files, use the following commands:
chown zenworks:zenworks /opt/novell/zenworks/install/downloads/novell-*.msi
chown zenworks:zenworks /opt/novell/zenworks/install/downloads/novell-*.msi.superceded