602: Unable to start the ZENworks Inventory service

Source:  ZENworks Desktop Management; Workstation Inventory; Inventory Service Manager

Severity:  Critical

Possible Cause:  The Inventory Service is unable to bind to the port specified in the Inventory_server_installation_directory\zenworks\inv\server\wminv\properties\
config.properties file.

Possible Cause:  Another application is binding to the same port number.

Action:  Do the following:

  1. Modify the port number in the Inventory_server_installation_directory\zenworks\inv\server\wminv\properties\config.properties file. For more information, see "Understanding the Server Configuration Service" in "Workstation Inventory" in the Novell ZENworks 6.5 Desktop Management Administration Guide.

  2. Restart the Inventory services. For more information, see "Starting and Stopping the Inventory Service" in "Workstation Inventory" in the Novell ZENworks 6.5 Desktop Management Administration Guide.

Possible Cause:  The Inventory server is already loaded.

Action:  In this case, this message is informational.