H.6 November 2009 (OES 2 SP2)

Updates were made to the following sections. The changes are explained below.

H.6.1 Upgrading the NSS Media Format

H.6.2 Planning NSS Storage Solutions

Location

Change

Section 5.4.2, Number of Characters Allowed

Updated the table for the maximum number of characters allowed from NSSMU and iManager for RAID 1, RAID 0+1, and RAID 5+1.

H.6.3 Using NSS in a Virtualization Environment

Location

Change

Section 6.1.3, Guest Server Issues

The XenBlkBarriers commands are modified.

H.6.4 Cluster-Enabling Shared NSS Devices and Pools with Novell Cluster Services

Location

Change

Section 8.2, Guidelines for Cluster-Enabling NSS

A new "Cluster-Enabling an Existing NSS Pool and Its Volumes" paragraph is added.

H.6.5 Management Tools for NSS

Location

Change

Prerequisites for Using the Storage-Related Plug-Ins

A new prerequisites “Web Browser Character Encoding Setting” is added.

Section 9.2, NSS Management Utility (NSSMU) Quick Reference

The table is updated.

H.6.6 Managing Devices

Location

Change

Section 10.6, Initializing a Disk

Added steps to initialize a disk from NSSMU.

Section 10.7.3, Configuring the Device’s Share State

Updated steps to configure the device’s share state from NSSMU.

H.6.7 Managing NSS Software RAID Devices

Location

Change

Section 13.2.4, Choosing a Software RAID Solution

Updated the table for RAID 0+1 and RAID 5+1.

Section 13.9, Creating a Software RAID 0+1 with NSSMU

Modified the section for RAID 0+1 and for the availability on Linux.

Section 13.10, Creating a Software RAID 5+1 with NSSMU

Modified the section for RAID 5+1 and for the availability on Linux.

Section 13.14, Replacing a Failed Segment in a Software RAID

Updated the table for RAID 0+1 and RAID 5+1.

H.6.8 Managing NSS Pools

Location

Change

Section 15.13, Updating eDirectory Pool Objects

Updated the steps for updating eDirectory from NSSMU and added a new note to the section.

Section 15.14, Updating eDirectory for Shared Pool

Added a new section.

H.6.9 Managing NSS Volumes

Location

Change

Section 18.1.1, Volume Attributes

The section is Lookup Namespace modified.

Section 18.10, Configuring the Name Space for an NSS Volume

The section is modified for Lookup Namespace.

H.6.10 Managing Hard Links

Location

Change

Section 24.4, Creating a Hard Link Using Ln on an NSS Volume

The command is modified.

H.6.11 Troubleshooting the NSS File System

H.6.12 NSS Commands

Location

Change

Section A.15, LAF Audit Log Messages Commands

The commands are updated.

Section A.26, Pool Management Commands

The Pool Status commands are updated.

Section A.31, Read Ahead Blocks and Allocate Ahead Blocks Commands

The Allocate Ahead Blocks commands and range are updated.

H.6.13 NSS Utilities

Location

Change

Section B.1, attrib

-S and -r options are added.

Section B.2, compfix

COMPFIX for Linux is updated.

Section B.11, rights

RIGHTS for Linux is updated.

Section B.13, quota

This is a new entry.

Section B.14, nssraid

This is a new entry.

Section B.15, ncsinit

This is a new entry.